Bâtiment
Glycol Cooling Heating Control System
|
Type | KRY-5A25W | ||
Medium Temp. range | -40℃~100℃ | -45℃~120℃ | |
Control mode | Feedforward PID+our special dynamic control calculation, PLC controller | ||
Temp. control | Control ethylene glycol solution temp. | Control inner box temp. | |
Program editor | 10 programs, each program can edit 45 steps | ||
Communication protocol | MODBUS RTU protocol, RS 485 interface | ||
Temp. feedback | Heat-conducting medium: PT100 (oil inlet,oil outlet and heater temp. measure) 3 temp. Measuring points |
single temp.measuring | |
Temp. accuracy | ±0.5℃ | ±0.3℃ | |
Heating power | 25kW | 9kW | |
Cooling capacity | 100℃ | 25kW | 9kW |
20℃ | 25kW | 9kW | |
0℃ | 25kW | 9kW | |
-20℃ | 25kW | 9kW | |
-40℃ | 10kW | 4kW | |
Internal circulation | 2400m³/h | ||
wind flow rate | |||
Circulation pump | Max110L/min 2.5BAR | ||
Compressor | Dorin | Emerson | |
Expansion valve | Emerson | ||
Oil separator | Emerson | ||
Evaporator | KAORI plate heat exchanger | Copper aluminum-fin | |
Operation panel | 7-inch touch screen, temperature curve record/excel data output | ||
Safety protection | Self-diagnosis function; freezer overload protection; high-pressure switch; overload relay; thermal protection device, liquid low-level protection, high-temperature protection and temperature |
||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||
Refrigerant | R-404A | ||
Connection size | DN25 PN10 | ||
Water-cooled type W | 8.5m³/h 1.5bar~4bar cooling water@25℃ | ||
Water-cooled condenser | Shell and tube exchanger | ||
Power | 380V 50HZ 57kw(max) |
Maintenance of Glycol Cooling Heating Control System
Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control glycol refrigeration system are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Refrigeration sort out related maintenance, so that you can use it in time.
Screw Compressor
Screw compressor is a very important part of ethylene glycol refrigerator, and the compressor is directly related to the stability of the unit. If the compressor has something wrong, In view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so it needs to be paid more attention in the ordinary use process in using.
Condensers and Evaporators
Is there is something wrong with the Glycol cooling heating control system, in view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so the compressor needs to be paid more attention in the ordinary use process.
Washing of condensers and evaporators
The cooling water of the water-cooled condenser of glycol refrigeration unit is open loop circuit. The circulating water is usually used by the cooling tower. When calcium the content of salt and magnesium salt in water is large, it is easy to decompose the fouling between the pipe and rock, and the heat transfers. Once the scale of the condenser of glycol cooling system is too thick, the cross section of the cooling water will decrease, the water volume will decrease and the condensing pressure will increase. Therefore, when the water quality of the cooling water is poor, the cooling water pipe should be washed at least once a year to remove scale and other contaminants. Of course, not only glycol cooling system but other other related cooling equipment used for a period of time, their maintenance knowledge is needed to learn in everyday use.
Bonne affaire : acheter au vendeur
Cette page concerne les importateurs et exportateurs de Glycol Cooling Heating Control System Rechercher dans la catégorie : Bâtiment Rechercher dans la catégorie : system, glycol, cooling, control, heating |
Vendredi 14 août 2015
Quantité : 200 at lea - Prix : To be discussed
Key Specification: - Color: Various color can be chosed - Input Voltage: 120~240V - Rated Power: 50-60HZ - Power (W): 36~55W - Noise Level: 25~55dB - Display Mode:LED - Control Mode: Touch screen - CADR: 320m³/H - Purifying Rate: 99.7% - Length Of Power Cord: 2...
Jeudi 02 avril 2015
SPECIFICATION : Frame Spark Carbon / IMP technology / HMX / BB92 / Carbon swingarm with 160PM U-Mono Link / Tapered Headtube IDS SL dropouts for 142 × 12mm BB height adj. Travel Front 120mm Rear 120 - 85 - Climb / Shock 190 × 50 Fork FOX 32 Float Factory CTD Air / Kashima...
Jeudi 27 septembre 2012
Quantité : conference - Prix : conference with clie
This Auto Stainer provides fast, easy and stable staining process for staining sputum specimen (for detecting Tubercle Bacillus) according to Fluorochrome staining method by automated system control. This new innovated stainer features advanced functions and performances over manual...