Informatique
EST-HS2 Manual Durometer Test Stand |
|
Operating Type |
Inverter to specimen |
|
Loading Method |
Cam loading |
|
Loading Stroke |
18 mm |
|
Specimen Thickness |
60 mm |
|
Throat Depth |
65 mm |
|
Support Table(dia.) |
Φ116 mm |
|
Lifting Adjustment |
Screw adjustment |
|
Table Adjustment |
Three-point leveling |
|
Net Weight |
5.6 kg (excluding S weight) |
|
Package Weight |
7.6 kg (excluding D weight) |
Durometer Operating Test Stand Operation
1. Unpacking
1.1 Take out the durometer test stand from the carton and remove the two packing foam inserts
1.2 Unbundle the webbing strap and remove the foam sheet and foam pad
1.3 Install the handle of durometer stand
2. Weights Selection of Durometer Stand
3. Simple Adjust for Support Table
In most applications, simple adjustments are usually sufficient for the durometer operating stand.
3.1 Release Tighten screw, turn height adjust knob, let durometer stand move down to contact on the support table.
3.2 Adjust 2 Vernier Knobs. Let the face of the support table be fully fitted to the bottom of the durometer operating stand.
4. Install Durometer Operating Test Stand
4.1 Lift Handle to put down durometer stand
4.2 Tighten Durometer Stand through Tighten Knob
5. Fine Adjust for Support Table
When accurate measurements or calibration are performed, fine adjustments to the support table may be required.
5.1 Set the test mode of the durometer test stand to Timing Mode and set its Dwell Time as long as possible, such as 99 s. (Lengthening the time period for reading lock)
5.2 Put standard thickness block between press foot and the support table.
5.3 Lift the handle to make the indenter of the durometer stand press onto the support able through the hole on the block.
5.4 Now the readings are displayed on the durometer test stand. Adjust the Vernier Knobs to make the reading as larger as possible to near 50HS.
Note:
1. If adjustment is not finished in setting time, lift the durometer operating stand then press again for renewing the timing.
2. Because the indenter is often pressed into the table, the reading does not must be "50.0 HS", It is usually less than 50.0 HS. Just adjusting the table to the location of the maximum reading.
3. Too large or too fast adjusting may damage the indenter (especially for type D). So it is better to pre-adjust with the durometer test stand loaded. Or lift up and press down the durometer stand in adjustment.
As a measuring instruments manufacturing company, we have types of force gauge meter for sale, if you have needs, please contact us.
Bonne affaire : acheter au vendeur
|
Cette page concerne les importateurs et exportateurs de EST-HS2 Manual Durometer Test Stand Rechercher dans la catégorie : Informatique Rechercher dans la catégorie : manual, durometer, stand, test |
Saturday 18 April 2015
Quantité : 100000 - Prix : 200 per pallet
Boisson d'énergie de Power Horse Avec autant de produits actuels (dont la performance est peu plus qu'une réclamationfondée sur hype) laissant les consommateurs se sentant trahis, c'est le symbole ducheval a représenté puissance et la force du monde au cours des siècles et constitue...
Monday 04 March 2013
Quantité : 30 - Prix : $495.00
Iphone 5 is the long-awaited model of the Apple company and one of the most anticipated events in the world of telecommunications 2012. It is characterized by harmonious dimensions that are much smaller than its predecessor, and this is also one of the thinnest smartphone in the world...
Sunday 15 March 2015
TAYSAN MAKINA CO. Sarl. Est une entreprise qui fait la production des machines types R entièrement automatiques et manuel à fabriquer du sucre en cubes dur en Turquie et aussi des machines à emballage alimentaires divers et sucre en morceaux depuis une expérience de dix ans. Avec...