Médical
Rotatable Sphincterotome
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
REF |
Structure |
Tip Length |
Cutting Length |
Working Length |
Compatible Guidewire |
Minimum Working Channel (mm) |
Unit/Box |
|
standard |
(mm) |
(mm) |
|||||
|
RST0425N |
3-lumen |
4 |
25 |
1900 |
0.035” |
2.8 |
1 |
|
RST0430N |
3-lumen |
4 |
30 |
||||
|
RST0725N |
3-lumen |
7 |
25 |
||||
|
RST0730N |
3-lumen |
7 |
30 |
Rotatable Sphincterotome (Preassembled with Guidewire)
|
REF |
Structure |
Catheter |
Tip Length |
Cutting wire Length |
Minimum Working Channel (mm) |
Guide Wire |
Unit/Box |
||||
|
Standard |
Outer Diam. |
Length |
(mm) |
(mm) |
Diam. (inch) |
Length (mm) |
Tip Shape |
Hardness |
|||
|
(mm) |
(mm) |
|
|
||||||||
|
RST0425NGW0206 |
3-lumen |
2.4 |
1900 |
4 |
25 |
2.8 |
0.035 |
4500 |
Straight |
Normal Stiff |
1 |
|
RST0430NGW0206 |
3-lumen |
2.4 |
1900 |
4 |
30 |
0.035 |
4500 |
||||
|
RST0725NGW0206 |
3-lumen |
2.4 |
1900 |
7 |
25 |
0.035 |
4500 |
||||
|
RST0730NGW0206 |
3-lumen |
2.4 |
1900 |
7 |
30 |
0.035 |
4500 |
||||
|
RST0425NGW0230 |
3-lumen |
2.4 |
1900 |
4 |
25 |
0.035 |
4500 |
Super Stiff |
|||
|
RST0430NGW0230 |
3-lumen |
2.4 |
1900 |
4 |
30 |
0.035 |
4500 |
||||
|
RST0725NGW0230 |
3-lumen |
2.4 |
1900 |
7 |
25 |
0.035 |
4500 |
||||
|
RST0730NGW0230 |
3-lumen |
2.4 |
1900 |
7 |
30 |
0.035 |
4500 |
||||
Comparison Between a Rotatable Sphincterotome and a Conventional Sphincterotome
The conventional sphincterotome consists of a metal wire with insulating coating, with the distal 20–30 mm of wire exposed, and a short radio-opaque, tapered tip. Cannulation is usually attempted with a sphincterotome at present time. The conventional sphincterotome is designed to perform sphincterotomy at the 12 o'clock orientation, while a rotatable sphincterotome for ERCP in B-II patients or when cannulation/therapeutic interventions entails orientation other than the standard 11–1 o'clock position.
As one of endoscopy device companies, we will do our best to meet all the needs of customers.
Bonne affaire : acheter au vendeur
|
Cette page concerne les importateurs et exportateurs de Rotatable Sphincterotome Rechercher dans la catégorie : Médical Rechercher dans la catégorie : rotatable, sphincterotome |
Sunday 13 September 2015
Quantité : 1 - Prix : 1,00 €
- Quick Details - - Light Source: LED - Item Type: Light Strips - LED Light Source: San An - Type: Flex LED Strips - Input Voltage(V): AC220V - Lamp Power: 14.4W - Lamp Luminous Flux(lm): 12-14LM - ): ">CRI (Ra>): 80 - Color Temperature(CCT): 6000K-6500K ...
Thursday 10 March 2016
Introduction: WT2080 LED Power Driver Test Instrument is the comprehensive test instrument for LED drive power which is according to GB/T 24825-2009 and IEC 62384: 2006. It can measure the following parameters: Input Characteristics Test (AC&DC), Output Characteristics Test (AC...)
Wednesday 21 October 2015
Specification: LSG-3000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 requirement. The LSG-3000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources...