Divers
Fire Resistant Control Cable (2-4cores) 300-500V
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Conductor |
rated voltage 300/500v |
||||||
|
|
Without Earth Conductor |
With Earth Conductor |
|||||
|
No. of Core X Cross Section |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
Nominal Overall Diameter |
Approx. Weight |
|
No*mm虏 |
No./mm |
mm |
mm |
mm |
kg/km |
mm |
kg/km |
|
2 Cores |
|||||||
|
2x1.5 |
7/0.53 |
0.5 |
0.5 |
7.7 |
70 |
8.2 |
80 |
|
2x2.5 |
7/0.67 |
0.5 |
0.5 |
8.8 |
100 |
9.6 |
120 |
|
2x4 |
7/0.85 |
0.5 |
0.5 |
9.8 |
140 |
10.5 |
170 |
|
3 Cores |
|||||||
|
3x1.5 |
7/0.53 |
0.5 |
0.5 |
8.7 |
90 |
10.5 |
100 |
|
3x2.5 |
7/0.67 |
0.5 |
0.5 |
9.5 |
125 |
10.7 |
150 |
|
3x4 |
7/0.85 |
0.5 |
0.5 |
11.5 |
180 |
12.5 |
220 |
|
4 Cores |
|||||||
|
4x1.5 |
7/0.53 |
0.5 |
0.5 |
10.3 |
105 |
12.2 |
120 |
|
4x2.5 |
7/0.67 |
0.5 |
0.5 |
11 |
155 |
13 |
190 |
|
4x4 |
7/0.85 |
0.5 |
0.5 |
12.5 |
255 |
13.5 |
270 |
Description of Fire Resistant Control Cable (2-4cores) 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 times of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
|
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
|
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
|
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fireproof Electrical Cable (2-4cores) 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As one of fire resistant cable suppliers, we can offer kinds of 2 core fire resistant cable for sale, if you have needs, please contact us.
There are many flexible cable manufacturers in China, but we are one of the best choices for you.
Bonne affaire : acheter au vendeur
|
Cette page concerne les importateurs et exportateurs de Fire Resistant Control Cable (2-4cores) 300-500V Rechercher dans la catégorie : Divers Rechercher dans la catégorie : 4cores, fire, resistant, cable, control, 500v |
Thursday 02 April 2015
SPECIFICATION : Frame Spark Carbon / IMP technology / HMX / BB92 / Carbon swingarm with 160PM U-Mono Link / Tapered Headtube IDS SL dropouts for 142 × 12mm BB height adj. Travel Front 120mm Rear 120 - 85 - Climb / Shock 190 × 50 Fork FOX 32 Float Factory CTD Air / Kashima...
Sunday 23 September 2012
Quantité : Minimum Or - Prix : T/T in advance, L/C
This Auto Stainer provides fast, easy and stable staining process for staining sputum specimen (for detecting AFB, Tubercle Bacillus) according to Ziehl-Neelsen staining method by automated system control and slide heating system. This new innovated stainer features advanced functions...
Friday 14 August 2015
Quantité : 200 at lea - Prix : To be discussed
Key Specification: - Color: Various color can be chosed - Input Voltage: 120~240V - Rated Power: 50-60HZ - Power (W): 36~55W - Noise Level: 25~55dB - Display Mode:LED - Control Mode: Touch screen - CADR: 320m³/H - Purifying Rate: 99.7% - Length Of Power Cord: 2...