Copper Tape Screened Control Cable |
Cross-Sectional Area |
Thickness of Insulation |
Thickness of Copper Tape |
Thickness of Sheath |
Overall Diameter (mm) |
Min resistance of insulation at 70℃ |
Max.D.C resistance of at 20℃ |
Approx Weight |
Approx Weight |
|
mm² |
mm |
mm |
mm |
min |
max |
MΩ/km |
MΩ/km |
(kg/km) |
(kg/km) |
4x0.75 |
0.6 |
0.05-0.1 |
1.2 |
8.1 |
9.7 |
0.012 |
24.5 |
144 |
144 |
4x1 |
0.6 |
0.05-0.1 |
1.2 |
8.4 |
10.2 |
0.011 |
18.1 |
153 |
153 |
4x1.5 |
0.7 |
0.05-0.1 |
1.2 |
9.5 |
11.4 |
0.011 |
12.1 |
190 |
190 |
4x2.5 |
0.8 |
0.05-0.1 |
1.5 |
10.9 |
13.1 |
0.01 |
7.41 |
276 |
276 |
4x4 |
0.8 |
0.05-0.1 |
1.5 |
12.5 |
15.1 |
0.0085 |
4.61 |
367 |
367 |
4x6 |
0.8 |
0.05-0.1 |
1.5 |
13.6 |
16.5 |
0.007 |
3.08 |
467 |
467 |
4x10 |
1 |
0.05-0.1 |
1.7 |
17.1 |
20.7 |
0.0065 |
1.83 |
728 |
728 |
7x0.75 |
0.6 |
0.05-0.1 |
1.2 |
9.3 |
11.2 |
0.012 |
24.5 |
178 |
178 |
7x1.0 |
0.6 |
0.05-0.1 |
1.2 |
9.7 |
11.7 |
0.011 |
18.1 |
209 |
209 |
7x1.5 |
0.7 |
0.05-0.1 |
1.5 |
11 |
13.3 |
0.011 |
12.1 |
239 |
239 |
7x2.5 |
0.8 |
0.05-0.1 |
1.5 |
13.3 |
16.1 |
0.01 |
7.41 |
398 |
398 |
7x4 |
0.8 |
0.05-0.1 |
1.5 |
14.6 |
17.6 |
0.0085 |
4.61 |
528 |
528 |
7x6 |
0.8 |
0.05-0.1 |
1.5 |
16 |
19.4 |
0.007 |
3.08 |
717 |
717 |
7x10 |
1 |
0.05-0.1 |
1.7 |
20.7 |
25.1 |
0.0065 |
1.83 |
1145 |
1145 |
10x0.75 |
0.6 |
0.05-0.1 |
1.5 |
11.3 |
13.7 |
0.012 |
24.5 |
214 |
214 |
10x1 |
0.6 |
0.05-0.1 |
1.5 |
12.5 |
15.1 |
0.011 |
18.1 |
300 |
300 |
10x1.5 |
0.7 |
0.05-0.1 |
1.5 |
14.2 |
17.2 |
0.011 |
12.1 |
367 |
367 |
10x2.5 |
0.8 |
0.05-0.1 |
1.7 |
16.5 |
20 |
0.01 |
7.41 |
572 |
572 |
10x4 |
0.8 |
0.05-0.1 |
1.7 |
18.6 |
22.5 |
0.0085 |
4.61 |
787 |
787 |
10x6 |
0.8 |
0.05-0.1 |
1.7 |
20.5 |
24.8 |
0.007 |
3.08 |
992 |
992 |
Description of Copper Tape Screened Control Cable
Conductor: Solid or Stranded Copper
Insulation: PVC/PVC(XLPE)
Screen: Copper tape Screen
Sheath: PVC
Rated voltages: 450/750V
Max. Continuous working temp of conductor: 70
Upon short circuit (Max. Duration time 5s) the Max.
Temperature of conductor not higher than160°C;
Ambient temperature of installation not less than 0°C.
Standard: IEC 60227, IEC60228, AS/NZS 5000.2
China Standard: GB9330
Application Of Copper Tape Screened Control Cable
The control cable with copper tape for cable screen features moisture-proof, corrosion-resistant and damage-proof. These copper tape screen control cables widely used as the connecting wire of instrument insulation, control equipment and power distribution facilities.
As a professional flex cable factory, we can offer different kinds of low smoke zero halogen power cable for sale, if you are interested, please contact us.
Bonne affaire : acheter au vendeur
Cette page concerne les importateurs et exportateurs de Copper Tape Screened Control Cable Rechercher dans la catégorie : Informatique Rechercher dans la catégorie : tape, control, screened, cable, copper |
Vendredi 27 septembre 2013
Quantité : 7 - Prix : 1,00 €
Nous vendons sauf vente entre temps ces nos 7 machines RYOBI qui sont disponible de suite : * Ryobi 512, Année 1997 36,5x52 - 2 couleurs - Mouillage Standard - Margeur à Nappes - Contrôle du réctificateur et du double feuille - Barres de calage rapide - Cylindre d'impression chromé...
Mercredi 05 août 2015
Nous vendons sauf vente entre temps la machine suivante : * Heidelberg SM74-5-H, Année 2004 52x74 - 5 Couleurs - env. 140 mio impressions Modèle SE, Vitesse 13.000 fph Equipée avec : . CP 2000 PrintCenter (avec MasterLevel and PresetLink) . Autoplate (Calage de Plaques Semi-Automatique) ...
Samedi 15 novembre 2014
Nous vendons sauf vente entre temps la machine suivante : * Roland R 304 HOB-E+LV - Année 1999 53x74 - 4 couleurs + Groupe Vernis avec "Chambre à Racle Tresu" et Cylindre Anilox - Pompe d'alimentation en Vernis. Pupitre RCI 2 - CCI Roland avec ColorPilot Grapho Metronic - CPL...