Recherche / Achat
Fire Resistant Single Core 300-500V
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Nominal Cross Section Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Without Earth Conductor |
|
|
mm² |
No./mm |
mm |
mm |
Nominal Overall Diameter |
Approx. Weight kg/km |
|
mm |
|||||
|
1.5 |
7/0.53 |
0.5 |
0.5 |
4.4 |
29 |
|
2.5 |
7/0.67 |
0.5 |
0.5 |
4.9 |
40 |
|
4 |
7/0.85 |
0.5 |
0.5 |
5.5 |
55 |
Description of Fire Resistant Single Core 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 time of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
|
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
|
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
|
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Single Core 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As a reliable electric cable factory, we can offer sorts of xlpe insulated cable for sale, if you are interested, please contact us.
Bonne affaire : acheter au vendeur
|
Cette page concerne les importateurs et exportateurs de Fire Resistant Single Core 300-500V Rechercher dans la catégorie : Recherche / Achat Rechercher dans la catégorie : core, single, fire, resistant, 500v |
Sunday 02 September 2007
LA CELLULETTE est la 1° sandale minceur avec tests d'efficacité effectués par un laboratoire Français agréé, prouvant un amincissement significatif en 28 jours d'utilisation. Une efficacité amincissante et anti capitons prouvée scientifiquement. Cette sandale présente une semelle...
Tuesday 12 May 2026
Oleícola San Francisco est un moulin-entreprise de taille familiale, spécialise dans l'élaboration artisanale d'Huile d'olive de qualité, dans le respect de la tradition et de l'environnement, pour le marché national et international. La gamme BIO "San Francisco olive ecológico"...
Thursday 14 March 2013
Quantité : 2 - Prix : 300,00 €
Anilutum Brand Cardigan sweater men's autumn and winter sweater sweaters men S243406 Made In China Model Number S243406 Brand Name Anilutum Gender Men's Material Polyester Season Autumn Type Coat Brand Anilutum The New The British Gentleman Slim Small Suit Jacket Brand...