Fire Resistant Single Core 300-500V
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Nominal Cross Section Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Without Earth Conductor |
|
|
mm² |
No./mm |
mm |
mm |
Nominal Overall Diameter |
Approx. Weight kg/km |
|
mm |
|||||
|
1.5 |
7/0.53 |
0.5 |
0.5 |
4.4 |
29 |
|
2.5 |
7/0.67 |
0.5 |
0.5 |
4.9 |
40 |
|
4 |
7/0.85 |
0.5 |
0.5 |
5.5 |
55 |
Description of Fire Resistant Single Core 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 time of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
|
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
|
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
|
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Single Core 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As a reliable electric cable factory, we can offer sorts of xlpe insulated cable for sale, if you are interested, please contact us.
Bonne affaire : acheter au vendeur
|
Cette page concerne les importateurs et exportateurs de Fire Resistant Single Core 300-500V Rechercher dans la catégorie : Recherche / Achat Rechercher dans la catégorie : core, resistant, fire, single, 500v |
Monday 04 March 2013
Quantité : 30 - Prix : $395.00
It's not just phone we're talking about... it's smart phone... it's Samsung GALAXY S III. It has the looks and a symmetry which would make you proud to hold it in your hands. You couldn't ask for more imposing façade than its 4.8 inches HD Super AMOLED high-definition display. It delivers...
Tuesday 17 March 2026
Bonjour Nous sommes une société artisanale de marbre fossilisé (la pierre d'erfoud SARL), qui s'intéresse aux effets géologiques de la région d'erfoud sud du Maroc. Nos activités sont variées : la fabrication, de tous les types de marbre fossilisé, en particulier le marron et le noir...
Saturday 19 July 2014
Cool White LED with color temperature 7000K to 7500K implies a mild blue tint in the white glow. Cool White is preferred in many applications because the light they output makes items illuminated appear crisper. Cool White is often preferred in bathrooms and other task areas. Note...