Chine (Rép. pop) Divers
Divers

2021 New design automatic circuit recloser/ Auto recloser

TD-CHZ16 protector integrates intelligent control functions such as over-current and short-circuit protection, under-voltage/over-voltage protection, leakage protection, remote communication management/fault memory, detection before closing, and automatic reclosing device. The new generation TD-CHZ16 protector has the characteristics of intelligence, safety, wide application range, stability and long service life.

Function of auto recloser

1. Short circuit protection:

When the current of the auto-reclosing leakage protector is greater than 3 times the rated current, the auto-reclosing leakage protector will be disconnected within 0.1 second to ensure the safety of the equipment.

2. Leakage Protection:

The leakage current of TD-CHZ16 factory setting is 30ma. When a 1530mA leakage occurs on the wire, the automatic circuit recloser will be disconnected within 0.1 second.

3. Overcurrent/load protection:

TD-CHZ16 type protector realizes the rated current 6A-10A-16A adjustable, and the maximum support is 16A. When the current is greater than 1.15 times the rated current, the auto-reclosing will monitor the duration and magnitude of this current; if the duration exceeds 3 seconds or is greater than 3 times the rated current, The automatic reclosing leakage protection switch is disconnected for protection

4. Overvoltage protection:

When the supply voltage is higher than 275V±5V, the auto-reclosing will be disconnected. After the voltage drops back to normal, the auto-reclosing will automatically close and energize.

5. Undervoltage protection:

When the power supply voltage is lower than 150V±5V, the automatic reclosing will be disconnected. After the voltage rises to normal, the automatic reclosing will automatically close, The power-on operation status is normal.

6. Detection before closing:

The automatic reclosing detects the line voltage before closing. When the power supply voltage is abnormal under-voltage or over-voltage, it will block the closing

and Alarm; if the fault is not eliminated, the switch cannot be closed and energized. When the fault is removed, the switch will automatically close and energize.

7. Auto reclosing characteristics: (adjustable)

When there is an instantaneous leakage or an instantaneous impact on the line, such as lightning, socket flashover, etc., and there may be danger, the automatic reclosing leakage protector will be disconnected immediately;

After the fault, if the line is safe, the auto-reclosing will automatically reclose and energize. The number of closing times is unlimited

8. Manual on-off performance

8.1. When the test button is pressed manually for leakage, the neutral wire and the live wire are disconnected correspondingly, and there is no output. After 60 seconds, it will automatically close, and the auto-reclosing protector will work normally.

8.2 After the power switch is manually turned off, the two relays are disconnected at the same time, and there is no output. The on-off action time is less than 0.1 second. Restart the switching power supply and output both at the same time.

For more information about auto recloser working principle and signal surge protector, please feel free to contact us!

If you are looking for a reliable surge protector supplier, don't hesitate to contact us!

Localisation : Build D, Huafeng Hi-Tech Industrial park, Jinlan Road, Large Industrial Park, Pingshan district, Shenzhen, 518118 Shenzhen,
Personne à contacter : win Tech, 0755 86215101

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
2021 New design automatic circuit recloser/ Auto recloser

Rechercher dans la catégorie : Divers
Rechercher dans la catégorie :
design, recloser, automatic, auto, circuit
Full control PC under any OS, in BIOS mode, during boot, at Blue Screens

Wednesday 20 May 2015

AI101P Single Port KVM over IP The KVM over IP technology (IP-KVM) combines digital remote KVM access via IP networks with comprehensive and integrated system management. The IP-KVM defines a new class of remote KVM access devices that can save your money, time, space, and equipment...

ACAFA Information Co.

  • epanio
  • 335 - Dasi Township
  • +88 6 33 07 13 00
Latzhosen Damen Schweiz Gr.L locker Denim Overalls

Tuesday 06 January 2015

Gr.L Damen Casual Latzhose Hüftjeans Gr.L locker Denim Overalls Hüft Latzhose Pants Gurthose Hier haben wir eine coole Damen Latzhose, das lockere Design lässt Sie einen höchster Tragekomfort haben. Die flexible Besonderheit passt sehr gut zu einer Bluse oder longsleeve. Ihr Muss...

Euro-Sino

  • - Thun
Suisse Véhicule
U280 Auto LCD-Diagnoseprogramm für VW, Audi Orange

Saturday 10 January 2015

Speziell für Fahrzeughalter oder DIY Benutzer konzipiert Hilft Ihnen, auf Ihr Auto finden Sie Müheursachen (Störungssucher) der elektronisch kontrollierten Systeme Zum Anschluss U280 mit der Diagnosebuchse, liest der Fehlercode (DTC) gezeigt auf U280 vorlesen zu identifizieren, zu...

Euro-Sino

  • - Thun