AD3000-TPA Infant Resuscitator
Quantité : 5000 Prix : 15-2200USD
With safe, precise and controllable PIP (Peak Inspiratory Pressure) and PEEP (Positive End Expiratory Pressure), Pigeon Medical Infant Resuscitators are easy to operate and can provide temporaty breathing support. It is crucial for NICU units, Nurseries, Delivery and Transport System.
Working Principle of Infant Resuscitator AD3000-TPA
Neonatal resuscitation also known as newborn cpap neonatal resuscitation is an emergency procedure focused on supporting the approximately 10% of newborn children who do not readily begin breathing, putting them at risk of irreversible organ injury and death. Through positive airway pressure, and in severe cases chest compressions, medical personnel can often stimulate neonates to begin breathing on their own, with attendant normalization of heart rate. CPAP infant resusciatator can deliver a more controlled and consistent peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP), which helps to protect the newborn's lungs.
Features of Infant Resuscitator AD3000-TPA
Consistent Care
The easy-to-use T-Piece circuit reduce variations in care, ensuring each breath is delivered in a similar manner.
Do More With Less
Powered by 5L/min, NeoPIP requires less gas flow to operate, for less gas consumed and improved transport range.
Durable & Dependable
Each NeoPIP unit is built to last; a solid case and metal fittings resist damage leading to long service life.
Specification of Infant Resuscitator AD3000-TPA
|
Model |
AD3000-TPA |
|
Pressure gauge |
-2-10kPa(-20-100cmH2O) |
|
PIP |
@5 LPM,2-27 cmH2O |
|
@8 LPM,4-36 cmH2O |
|
|
@10 LPM,6-42 cmH2O |
|
|
@15 LPM,12-57 cmH2O |
|
|
CPCP/PEEP |
@5 LPM,0.3-6 cmH2O |
|
@8 LPM,0.8-14 cmH2O |
|
|
@10 LPM,1-17 cmH2O |
|
|
@15 LPM,2.5-23 cmH2O |
|
|
Noise |
≤50dB(A) |
|
Gas source |
0.3MPa-0.4MPa |
|
Recommended patient weightUp to 10KG |
|
Practical Application of Infant Resuscitator AD3000-TPA
Failure to breathe,including antepartum mechanism, recent intrapartum asphyxia, central nervous system depression, maternal drug abuse etc.
Failure to expand the lungs, including airway obstruction, respiratory distress syndrome, malformations involving the respiratory tract.
Personne à contacter : Zhou Alex , +18 8 98 65 17 88
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
|
Cette page concerne les importateurs et exportateurs de AD3000-TPA Infant Resuscitator Rechercher dans la catégorie : Médical Rechercher dans la catégorie : resuscitator, ad3000, infant |
Wednesday 14 September 2016
Quantité : 5000 - Prix : 50,00 €
Robinet à soupape PN 16/25/40 Acier moulé - Robinet à soupape PN 25‑40 - Construction suivant DIN 3356 - Diamètre : DN15 à DN300 - Chapeau boulonné à arcade - Presse-étoupe boulonné - Tige montante à filetage extérieur - Ecartement suivant EN 558‑1 Série 1 - Raccordement...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Sunday 12 July 2015
Quantité : 1 - Prix : 2 000,00 €
Factory Equipment: 1. 4 hole High-speed air turbine handpiece's connector 2 set 2. Low-speed handpiece tubing with connector 1 set 3. 3-way syringe (hot & cold) 2 piece 4. up-mounted instrument tray 1 set 5. Turnable ceramic cuspidor 1 set 6. Double joint headrest 1 set 7...
France Skylight International Limited
- 528500 - Foshan
- +15 0 19 61 17 04
Friday 01 May 2026
Unitronics OPLC V1210 – Automate Control Engineering Ltd. (winston@automate-ace.com) Vision1210: Industrial control processes can now enjoy full PLC functionality with a larger than ever 12.1”, 65K color-touchscreen. This controller is a perfect fit for the food industry- with its IP66 rating...
Automate Control Engineering Ltd.
- automatehk
- 999077 - Hong Kong
- +85 2 23 42 72 76
Paiement sécurisé





