Cooling Tower Drift Eliminator For Mesan
Quantité : 9000 Prix : USD10-USD1000000
The main function of drift eliminator in cooling tower is to prevent steam loss. Generally, it is placed above the filler of cooling tower, which can effectively prevent the occurrence of flying water phenomenon, avoid the loss of liquid water, and also avoid the loss of chemicals in circulating water, protect the ecological environment and save water resources. The water collecting efficiency of the drift eliminator is very high, and the air flow in the cooling tower will not be reduced. When the hot and humid air in the tower passes through the eliminator, it can block 75% - 90% of the water and reduce the drift rate to less than 0.001%.
Parameter Of Cooling Tower Drift Eliminator For Mesan
|
Module Length (Max) |
mm |
2440 |
|
Module Width (Max) |
mm |
500 |
|
Module Height |
mm |
130 |
|
Flute Height |
mm |
25 |
|
Sheet Thickness - Before Forming |
mm |
0.45 |
|
Sheet Thickness - After Forming |
mm |
0.38 |
|
Max. application temp. (short time) - PVC |
°C |
60 |
Advantages Of Cooling Tower Drift Eliminator For Mesan
1. Water removal efficiency and small ventilation resistance.
2. This drift eliminator of cooling tower has enough assembly stiffness, and its geometry should be stable under normal operation conditions, so as to ensure the stable resistance operation effect of the cooling tower water collector.
3. No deformation.
4. The drift eliminator assembly block of the cooling tower has enough rigidity and strength.
5. Simple structure, easy processing, and durable.
6. The utility model has the advantages of water collection efficiency, small air flow resistance, strength, no deformation, convenient installation and maintenance, long service life, good flame retardancy, etc.
As a professional cooling tower manufacturer, we provide cooling tower spare parts, counter flow cooling tower, drift eliminator of cooling tower, wet and dry cooling tower, etc. Want to know cooling tower drift eliminator efficiency or more, contact us.
Personne à contacter : AUVC ctauvc, 057582331987
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
|
Cette page concerne les importateurs et exportateurs de Cooling Tower Drift Eliminator For Mesan Rechercher dans la catégorie : Pro / B2B Rechercher dans la catégorie : eliminator, mesan, tower, drift, cooling |
Friday 15 December 2017
online katalogOEM PART NO DESCRİPİTİON 66072 Crown Wheel and Pinion FOR CARRARO 13X30 66941 Crown Wheel and Pinion 15x37 2277448 CATERPİLLAR AİR FİLTER OUTER 2277449 CATERPİLLAR AİR FİLTER İNNER 01/117901 FAN BELT 01/124403 FAN BELT 01/124404 02/100073 Oil Filter Canister Type, MEDİUM...
ANAC MAKINA CO LTD STI
- 34800 - İSTANBUL
- +905069691531
- +9005069691531
Friday 27 September 2013
Quantité : 7 - Prix : 1,00 €
Nous vendons sauf vente entre temps ces nos 7 machines RYOBI qui sont disponible de suite : * Ryobi 512, Année 1997 36,5x52 - 2 couleurs - Mouillage Standard - Margeur à Nappes - Contrôle du réctificateur et du double feuille - Barres de calage rapide - Cylindre d'impression chromé...
ACS DIFFUSION s.a.s.
- acsdiffusionsa
- 42952 - Saint-Etienne
- 0033 (0)4 77 92 77 88
- 06 10 63 37 83
Tuesday 24 September 2013
Quantité : 1000 - Prix : 1 000,00 €
ASME SA213 T11 , ASTM A213 , ASTM A213 T11, T11 SA213 , pipe en acier allié , tube en alliage ASTM A213 T11 est la partie de la norme ASTM A213 Standard Specification for Seamless ferritique et austénitique alliage d'acier chaudière , surchauffeur , tubes échangeurs de chaleur ...
Sunny Steel Tubosacero Ltd.
- tubosacero
- Shanghai - 闸北
- 862133780199
- 862161851035
Paiement sécurisé




