Chine (Rép. pop) Informatique
Informatique

DPM-6000 PM Monitor PM2.5/PM10

Quantité : 10,000   Prix : 0-50,000

Overview Of DPM-6000 pm monitor Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing environment and safety monitoring instruments as well as the latest demand at home and abroad, our company has launched a new generation DPM-6000 atmospheric particulate monitor with high accuracy, reliability, stability and economy. Our pm monitor can measure PM10, PM2.5 and dust particles of other cut sizes, widely applied in inhalable particles concentration detection in environmental atmosphere monitoring.

Design of instrument meets US EPA and national standard

Adopt PM filter membrane enrichment technology

Particle cutter meets EPA standard TSP, PM10, PM2.5

Use simple, reliable mechanical transmission structure and modular design to ensure the measurement is accurate and reliable, and the pm monitor can operate stably for a long term.

PrincipleFeaturesSpecificationApplication

Principle Of DPM-6000 PM Monitor PM2.5/PM10

The monitoring principle of the pm monitor is mainly based on enrichment technology of atmospheric particulate and beta ray attenuation method. The pm 2.5 monitoring equipment concentrates on particulate matters whose aerodynamic equivalent diameter is smaller than 2.5/10μm on the rolled filter membrane. The air pollution analyzer adopts low-radiation 14C as a radioactive source. The emitted Beta-ray passes through the filter membrane with contaminants and will be received by the detector. The pm 2.5 measurement device is composed of a photo-multiplier tube (or Geiger detector), plastic scintillator and counter. The thickness of enrichment can be analyzed quantificationally according to Beta-ray energy that detector received, then the PM2.5/10 concentration in the air can be calculated.

Features Of DPM-6000 PM Monitor PM2.5/PM10

The design of the gas path keeps filter paper, a radioactive source and detector immovable during enrichment and measurement, ensuring a good lower detection limit.

US EPA standard beta ray attenuation method, which spares the complicated operations of TEOM, such as manually replace filter paper and weight. Compared to the light scattering method, our pm monitor has higher measurement accuracy.

Cutter, based on simulation verification of aerodynamics, will provide a various selection of accurate particle.

Sizes: PM1, PM2.5, PM10, TSP.

Sampling flow is measured by a mass flow sensor and corrected with collected ambient temperature and pressure to get the sampling flow of the field.

Use C14 source which is of low-density, low activity, and long half-life to realize stable measurement. No special protection for the pm measuring device is needed. Reliable and safe.

Flexible paper-pressing structure. Mechanical driving design of the pm 2.5 monitoring equipment is simple and reliable; greatly reduce paper breaking and paper jam and avoid the error caused by the moving of filter paper.

The pipeline heating system is used to eliminate interference from ambient humidity and make the detector fit into sudden.

Flow control system with precise closed-loop feedback; stable sampling flow and small error.

Various external ports, such as RS232/RS485, 4~20mA and etc.

Low maintenance frequency of the pm measuring device, once a year.

Specification Of DPM-6000 PM Monitor PM2.5/PM10

Measuring principle

Beta ray attenuation method

Performance Index

Measuring Range

0~1000μg/m3³or 0~10000μg/m3 (optional)

Radioactive Source

14C (carbon-14), radioactivity≤60μCi

Accuracy

≤5%

Display Resolution

1μg/m3

Lower Detection Limit

5μg/m3

Flow Error

≤±2% (generally set at 16.67L/min)

Sampling Flow Stability

≤±2% working point flow/24h

Sampling Period

≤1h (time is settable)

Sampling Flow

Default 16.67L/min

Parallelism

PM10≤10%, PM2.5≤15%

Filter Paper Tape

Filter Paper Tape

Glass fiber, inner diameter: 40 mm, width:30 mm, service time 1 month (work period 1 h)

Interface Para.

I/O

Rs232, RS485, 4-20mA, GPRS (optional)

Data Storage

One year

Working Condition

Cutting header

Ambient temperature (-40~50)℃, ambient pressure (80~106kPa)

Detector

Ambient temperature (5-40)℃, ambient pressure (80-106kPa), humidity (≤90%)

Power Supply

AC (220±22)V, (50±1)Hz

Dimension & Weight

483×407×322(mm) (L×W×H); Monitor 30kg, Pump 8kg

Application Of DPM-6000 PM Monitor PM2.5/PM10

Inhalable particle real-time monitoring in industry,, construction, residential district and etc.

Environment assessment, permission, and pollution forecast and pre-warning.

Ambient air quality monitoring and mobile air monitoring experimental station.

Occupational disease research, and long-term background environment research.

Secondary emission monitoring (coal storage area, wharf, etc.).

HANGZHOU ZETIAN TECHNOLOGY CO., LTD is a professional air pollution monitoring instruments manufacturers, we provide Water Quality Analyzers, Continuous Emission Monitoring & Process Control, Gas Analysis Modules, air quality monitor and etc. Want to know more? Please contact us.

Localisation : 1st Building of Taiheng Mansion, NO.22 Zhiren Street, Puyan, Binjiang District, Hangzhou, China, 310053 Hangzhou,
Personne à contacter : Alex Wang, +0086 18957111635

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
DPM-6000 PM Monitor PM2.5/PM10

Rechercher dans la catégorie : Informatique
Rechercher dans la catégorie :
monitor, pm10
Emirats arabes 6419 Bâtiment
PPR  supplier ppr  manufacturer in uae

Lundi 23 mai 2016

Quantité : 100000 met - Prix : 0.280usd

Thomsun Industries LLC is a professional PPR manufacturers and ppr suppliers in Dubai UAE. T-Mech pressure piping system is considered to be the best carrier of potable water, using the revolutionary raw material of PPR-80 of Borouge brand. T-Mech PPR major products range covers...

Thomsun industries LLC

  • Lily Kutty
  • 6419 - Dubai
  • +97 1 48 85 40 00
  • +971551188058
Taiwan 335 High Tech
DD1000TR Display Port Chainable Extender over CAT.5e/6

Mardi 05 août 2014

DD1000TR Display Port Chainable Extender over CAT.5e/6 The DD1000TR is the latest high performance, cost-effective Displayport Daisy-Chainable Extender over CAT.5e/6, extended up to 100m between. supports Full HD 1080p, 1920x1080, video and daisy-chainable with high flexibility...

ACAFA Information Co.

  • epanio
  • 335 - Dasi Township
  • +88 6 33 07 13 00
France 59590 Pro / B2B
Robinet à soupape - Corps Acier à soufflet Inox

Mercredi 14 septembre 2016

Quantité : 5000 - Prix : 50,00 €

Corps Acier A216 WCB & GS-C25 & 1.0619 & GP240GH - Clapet Inox 420 - Siège Inox 420 - Soufflet Inox 321 - Presse étoupe Graphite Tige et volant montants tournants - Chapeau et presse étoupe boulonnés - A brides RF PN16/ PN25/40 - Commande par volant fonte - Peinture...

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935