Chine (Rép. pop) Informatique
Informatique

High Precision Spectroradiometer Integrating Sphere System

Prix : 1,00 €

Basic Info.

Model NO.

LPCE-2

After-sales Service

Perfect

Warranty

24months

Trademark

LISUN

Origin

China

Product Description

LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM-80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and A molding integrating sphere with holder base. This sphere is more round and the test result is more accruacy than the traditional integrating sphere.

Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic
• LED Light Decay Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.

Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82

High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufactory or General Test Lab):
High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
• Stray light: <0.015%(600nm) and <0.03%(435nm)<br /> • Integration Time: 0.1~10,000ms
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9000C LMS-9000CUV-VIS LMS-9000CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm

Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab):
Scientific Grade CCD Spectroradiometer (LMS-9500C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050C), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector
• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm
• Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp)
• Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2%
• Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear Accuracy: ±0.2%
• Stray light: <0.015%(600nm) and <0.03% (435nm)<br /> • Integration time: 0.1ms-60s
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9500C LMS-9500CUV-VIS LMS-9500CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm
Localisation : 113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, 201802 Shanghai,
Personne à contacter : Rachel He, 860015317383997

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
High Precision Spectroradiometer Integrating Sphere System

Rechercher dans la catégorie : Informatique
Rechercher dans la catégorie :
sphere, spectroradiometer, high, integrating, system, precision
Taiwan 54559 Habillement / Mode
Seamless compression wear

Tuesday 17 March 2026

Quantité : 10000

1. Material: Nylon 90%, Spandex 10%. 2. There is rose pattern in the front of underpants. Beautiful and fashion. 3. It is not allergic when you are wearing it. 4. Size: S,M,L,XL,XXL 5. Style: Low, Medium and High waist. 6. Material option: Cooling material, Bamboo Charcoal material...

YSI INTERNATIONAL Co., Ltd.

Bulgarie Alimentaire
photo non disponible

Friday 27 January 2012

We offer you the following high quality products: - Hibernated snails, with expiration period of 12 months, temperature 1 - 6 C° - Blanched, deeply frozen snails with expiration period of 24 months, temperature -18 C°, packed in 0.5kg, 1kg and 2 kg bags. - Snail caviarLocalisation : "P...

Bulgarian Snails

Italie Divers
photo non disponible

Thursday 23 September 2010

O C M A : An ItalianCompany , for Project - Produce - Export any kind of Full Lifts ( ELEVATORS) Hydraulic and Electric (traction), for •Passengers / Panoramic / Parkings Car / Hotels / Hospitals / Home Lift – Plateform – Manufactories - High Buildings , And for Goods (upto 10 Tons) ...

OCMA Lifts

  • ocma
  • - Milano
  • 0039 3392071165