High Precision Spectroradiometer Integrating Sphere System
Prix : 1,00 €
Basic Info.
Model NO.
LPCE-2
After-sales Service
Perfect
Warranty
24months
Trademark
LISUN
Origin
China
Product Description
LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM-80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and A molding integrating sphere with holder base. This sphere is more round and the test result is more accruacy than the traditional integrating sphere.
Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic
• LED Light Decay Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82
High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufactory or General Test Lab):
High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure
Specification:
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
• Stray light: <0.015%(600nm) and <0.03%(435nm)<br />
• Integration Time: 0.1~10,000ms
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF
| LISUN Model | LMS-9000C | LMS-9000CUV-VIS | LMS-9000CVIS-NIR |
| Wavelength | 350-800nm | 200-800nm | 350-1050nm |
Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab):
Scientific Grade CCD Spectroradiometer (LMS-9500C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050C), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure
Specification:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector
• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm
• Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp)
• Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2%
• Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear Accuracy: ±0.2%
• Stray light: <0.015%(600nm) and <0.03% (435nm)<br />
• Integration time: 0.1ms-60s
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF
| LISUN Model | LMS-9500C | LMS-9500CUV-VIS | LMS-9500CVIS-NIR |
| Wavelength | 350-800nm | 200-800nm | 350-1050nm |
Personne à contacter : Rachel He, 860015317383997
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
|
Cette page concerne les importateurs et exportateurs de High Precision Spectroradiometer Integrating Sphere System Rechercher dans la catégorie : Informatique Rechercher dans la catégorie : sphere, spectroradiometer, integrating, precision, high, system |
Friday 02 July 2010
Quantité : FCL - Prix : FOB
We can supply RBD Palm oil is decent quantity with high quality. Our oil grade is CP 8 and we export from Malaysia.Localisation : 3 , Bukit Batok St 22 , #01-01, 659582 Singapore, Personne à contacter : Mohan Sinapillay, 65 62717030
Sunvision Marketing Pte Ltd
- sunvisionmarketingpteltd
- 659582 - Singapore
- 65 62717030
- 65 97887205
Friday 13 June 2008
Quantité : As per dem - Prix : Negotiable
We are the manufacturers and exporters of high quality of Leather Hats/Caps. We Leather Hats in various Leather and Colours, simple, water repellent, water proof qualities. Any desighn provided by client may also be developed.Localisation : Meera Manzal,Royal Street,Neka Pura, 51310 Sialkot...
Sayor Int'l.
- sayor
- 51310 - Sialkot
- +92 5 23 61 05 15
- 0092 321 7101608
Sunday 10 December 2006
SHINNYES a Patented Multipurpose high efficiency nano-grade plasma air purifier build-in stainless steel piping dust collector, its work 24hrs a day almost zero maintenance cost, dont cause air re-pollution with CE, FCC, LVD certificationLocalisation : No. 19-A, Jalan Jejaka 2, Taman...
Healthcare Worldwide
- freeads
- 55100 - Kuala Lumpur
- +60 3 92 83 00 80
- +60 1 62 02 31 03
Paiement sécurisé