Chine (Rép. pop) Biens d'équipement
Biens d'équipement

High Precision Spectroradiometer Integrating Sphere System

LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM-80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and a-molding integrating sphere with holder base. This sphere is more round and the test result is more accruate than the traditional integrating sphere.

Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, WPE, EQE, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic(Optional)
• LED Light Aging Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.

Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82

High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufacturer or General Test Lab):
High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detailed PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
• Stray light: <0.015%(600nm) and <0.03%(435nm)<br /> • Integration Time: 0.1~10,000ms
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can run in Win7, Win8, Win10, Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometry, Colorimetry and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9000C LMS-9000CUV-VIS LMS-9000CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm

Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab):
Scientific Grade CCD Spectroradiometer (LMS-9500C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050C), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector
• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm
• Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp)
• Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2%
• Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear Accuracy: ±0.2%
• Stray light: <0.015%(600nm) and <0.03% (435nm)<br /> • Integration time: 0.1ms-60s
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10, Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9500C LMS-9500CUV-VIS LMS-9500CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm
Localisation : 113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, 201802 Shanghai,
Personne à contacter : He Rachel, +15 3 17 38 39 97

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
High Precision Spectroradiometer Integrating Sphere System

Rechercher dans la catégorie : Biens d'équipement
Rechercher dans la catégorie :
high, system, spectroradiometer, integrating, sphere, precision
Turquie 34116 Destockage
photo non disponible

Friday 19 October 2007

Quantité : whatever n - Prix : negotiable

We export non-food supermarket products for the wholesale buyers for supermarkets as private label or brandname. we have a high-level experience in especially France, Portugal and other European countries.Localisation : Tahtakale, Uzuncarsi Cad. Milas Han, 182/215 Eminonu, 34116 Istanbul...

Gosterge Plastik Ltd.

  • gosterge
  • 34116 - Istanbul
  • 902125136617
  • 5323323228
France 93300 Téléphonie
Grossiste en accessoires de téléphonie et produits high-tech

Tuesday 23 June 2026

Découvrez tous nos articles high-tech et accessoires pour smartphones au sein de notre showroom situé à Aubervilliers ou directement sur notre boutique en ligne http://www.vipgros.com. Nous proposons un large choix d'articles pour les proffessionnels de la téléphonie et du multimédia...

EWAN

  • EWAN
  • 93300 - Aubervillers
  • 09 53 37 58 48
Roumanie 305500 Alimentaire
SPREADABLE COCOA CREAM

Tuesday 23 June 2026

Quantité : 1000 - Prix : Negotiable

SPREADABLE COCOA CREAM Dark creole chocolate - high quality spreadable cream, with high cocoa content - low melting point, for fresh mouth effect after consumption - ready to use, with a wide range of applications, from direct filling between cake layers, to fine creams obtained...

SC EUROCAS SRL