Installation of the HPLC Column

The installation of the HPLC column should be carried out in the following three steps:

a. Unpack the HPLC column and confirm the type, size, date of manufacture, and solvent stored in the column.

b. Unscrew the sealing plug from the joints at both ends of the column and put it back in the box for spare.

c. According to the flow direction indicated on the HPLC column, connect the inlet end of the column to the outlet of the injection valve through the connecting pipe (if the conditions permit, it is recommended to use the guard column in front of the column); the outlet of the column is connected with the detector. The connecting pipe is a stainless steel pipe having an outer diameter of 1.57 mm and an inner diameter of 0.1 to 0.3 mm.

Both ends of the connecting tube have a hollow screw and a sealing ring for sealing. Always try to reduce the dead volume outside the column when taking over. After the connecting tube passes through the hollow screw and the pressure ring, insert it as far as possible into the end, then tighten the hollow screw clockwise until it stops, then use the wrench to continue to screw 1/4-1/2 turn clockwise, remember not to use too much force.

If the HPLC column is leaking after being pressurized by the mobile phase, use a wrench to continue to turn 1/4 turn clockwise until it does not leak.

Localisation : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Personne à contacter : Bruce Lu, +86 29 89284429

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
Installation of the HPLC Column

Rechercher dans la catégorie : Divers
Rechercher dans la catégorie :
hplc, column, installation
Taiwan 414 Médical
New Design!! MSW-104 Bubble Bath Spa Massager Full Body Mattress Ozone Massage Non-Slip...

Mardi 08 mars 2016

Quantité : 100~500

Bubble Bath Spa Massager MSW-104 Bubble Bath Spa Massager is a new generation of home spa massager and is optimized for use in bath with the quality of tranquility, relaxing and luxury life. Configuration of MSW-104 is One-Touch Control Panel with Minimal and fashionable design...

LienJie International Ltd.

  • 414 - Taichung City
  • +886 4 23367128
France 529000 Biens d'équipement
2-Wire Standard Pear White LED Rope Light

Mardi 22 juillet 2014

Pearl white LED rope light emits a vanilla white color which is similar to neon white. It is manufactured by InGaN technology which is trustable and sophisticated, producing the exact customized white color we expect. It is made of vanilla PVC tubing, filled with bright white LED's...

Real Green lighting Company

  • Bonny Chan
  • 529000 - Jiangmen City
  • +15 6 02 20 39 93
France 59590 Pro / B2B
Vanne à passage direct

Mercredi 14 septembre 2016

Quantité : 5000 - Prix : 50,00 €

Gate Valves (F7 Type) DIN Standard F7 Gate valves / (Length acc.to DIN EN 558-1,face to face series 26 ) DIN F7 Gate valve DIN Absperrschieber F7 DIN Válvulas de compuerta F7 DIN F7 šoupátko stavební délka dle DIN EN558-1 serie 26 DIN Standard F7 sluseventil (lengde iht. DIN EN 558-1...)

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935