Chine (Rép. pop) Médical
Médical

MemoPart Atrial Septal Defect (ASD) Occluder

MemoPart

Accurate occluding, stable clamping

MemoPartAtrial Septal Defect (ASD) Occluder Details

ASD occluder device Description

MemoPartASD Occluder is a self-expanding double-disc nitinol mesh occlusion device. The 2 discs are connected by a short waist that relates to the defect size. Polyester fabric is securely sewn to each disc to increase occlusion. The device is visible under X-ray.

ASD occluder device Features

Modified rigidity and flexibility for different type of occluders - greater stiffness of Atrial Septal Defect Occluder (ASDO) offers excellent supporting force for big disks.

Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.

The hubless design of Atrial Septal Defect Occluder (ASDO) helps with earlier endothelialization to minimize the risk of thrombosis.

Indications for Use ASD Occlusion Device

The MemoPartASD Occluder is a percutaneous, transcatheter, atrial septal defect closure device intended for the occlusion of atrial septal defects ASDin secundum position or patients who have undergone a fenestrated Fontan procedure and who require closure of the fenestration.

Patients indicated for ASD closure have echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overloadi.e.,1.5: 1 degree of left-to-right shunt or RV enlargement .

Ordering Information

Atrial Septal Defect (ASD) Occluder

Catalogue No.

Device
Siz

A
Waist
Diameter
(mm)

B LA Disc Diameter (mm)

C
RA Disc
Diameter
(mm)

H
Waist
Length
(mm)

FQFDQ- Ⅰ 06

6

6

16

14

3

FQFDQ- Ⅰ 07

7

7

21

17

3

FQFDQ- Ⅰ 08

8

8

18

16

3

FQFDQ- Ⅰ 09

9

9

23

19

3

FQFDQ- Ⅰ 10

10

10

20

18

3

FQFDQ- Ⅰ 11

11

11

25

21

3

FQFDQ- Ⅰ 12

12

12

22

20

3

FQFDQ- Ⅰ 13

13

13

27

23

3

FQFDQ- Ⅰ 14

14

14

24

22

3

FQFDQ- Ⅰ 15

15

15

29

25

4

FQFDQ- Ⅰ 16

16

16

30

26

4

FQFDQ- Ⅰ 17

17

17

31

27

4

FQFDQ- Ⅰ 18

18

18

32

28

4

FQFDQ- Ⅰ 19

19

19

33

29

4

FQFDQ- Ⅰ 20

20

20

34

30

4

FQFDQ- Ⅰ 22

22

22

36

32

4

FQFDQ- Ⅰ 24

24

24

38

34

4

FQFDQ- Ⅰ 26

26

26

40

36

4

FQFDQ- Ⅰ 28

28

28

42

38

4

FQFDQ- Ⅰ 30

30

30

44

40

4

FQFDQ- Ⅰ 32

32

32

47

42

4

FQFDQ- Ⅰ 34

34

34

49

44

4

FQFDQ- Ⅰ 36

36

36

51

46

4

FQFDQ- Ⅰ 38

38

38

54

50

4.5

FQFDQ- Ⅰ 40

40

40

56

52

4.5

FQFDQ- Ⅰ 42

42

42

58

54

4.5

FQFDQ- Ⅰ 44

44

44

60

56

4.5

FQFDQ- Ⅰ 46

46

46

62

58

4.5

FQFDQ- Ⅰ 48

48

48

64

60

4.5

FQFDQ- Ⅰ 50

50

50

66

62

4.5

Hubless Atrial Septal Defect (ASD) Occluder

Catalogue No. Device

Device Size

A Waist Diameter (mm)

B LA Disc Diameter (mm)

C RA Disc Diameter (mm)

H Waist Length (mm)

WTFQFDQ- Ⅰ 06

06

6

16

14

3

WTFQFDQ- Ⅰ 07

07

7

21

17

3

WTFQFDQ- Ⅰ 08

08

8

18

16

3

WTFQFDQ- Ⅰ 09

09

9

23

19

3

WTFQFDQ- Ⅰ 10

10

10

20

18

3

WTFQFDQ- Ⅰ 11

11

11

25

21

3

WTFQFDQ- Ⅰ 12

12

12

22

20

3

WTFQFDQ- Ⅰ 13

13

13

27

23

3

WTFQFDQ- Ⅰ 14

14

14

24

22

3

WTFQFDQ- Ⅰ 15

15

15

29

25

4

WTFQFDQ- Ⅰ 16

16

16

30

26

4

WTFQFDQ- Ⅰ 17

17

17

31

27

4

WTFQFDQ- Ⅰ 18

18

18

32

28

4

WTFQFDQ- Ⅰ 19

19

19

33

29

4

<span style="font-family

Localisation : No.37 Chaoqian Road Changping District, Beijing, China, 102200 Beijing,
Personne à contacter : medical lepu, 86 10 80120666

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
MemoPart™ Atrial Septal Defect (ASD) Occluder

Rechercher dans la catégorie : Médical
Rechercher dans la catégorie :
defect, occluder, atrial, septal, memopart™
Chine (Rép. pop) Shanghai Matières premières
U virage tubes

Monday 23 September 2013

Quantité : 1000 - Prix : 1 000,00 €

Nous en faisons sortir une gamme exclusive de tubes coudés en U , qui sont connus pour leur qualité supérieure et une excellente fonctionnalité. Chaque tube de coude U de notre gamme est rigoureusement la qualité vérifiée par notre équipe de professionnels talentueux à chaque étape...

Sunny Steel Tubosacero Ltd.

  • tubosacero
  • Shanghai - 闸北
  • 862133780199
  • 862161851035
Chine (Rép. pop) 322000 Meubles
Women Metal Sunglasses

Tuesday 30 August 2016

Prix : 10,00 €

19003Fashion aviator sunglasses, ladies style. Sample lenses category 3, lens can be produced lighter or darker.Shiny gold frame with pink painting on temples, crystal pink tips.Smoke to pink gradient lenses. Also can be made in other colors.Metal hinge.Delivery time: 45 daysLens features...

Yiwu Fashion Zone Eyewear Co., Ltd muv

  • 322000 - YIWU
  • 86 0579 85557735
  • 0579 15868988024
Chine (Rép. pop) 116031 Biens d'équipement
High Quality Smart Differential Pressure Transmitters

Tuesday 23 February 2016

This pressure transmitter ( High Quality Smart Differential Pressure Transmitters ) using imported pressure sensor, temperature compensation of laser resistor trimming by using compute r, integrated wiring box design. With special terminal and digital display, installation, calibratio...

Dalian Teren Instruments Co,Ltd

  • 116031 - DALIAN
  • 86 18642631917