MemoPart Atrial Septal Defect (ASD) Occluder
MemoPart™
Accurate occluding, stable clamping
MemoPart™ Atrial Septal Defect (ASD) Occluder Details
ASD occluder device Description
MemoPart™ ASD Occluder is a self-expanding double-disc nitinol mesh occlusion device. The 2 discs are connected by a short waist that relates to the defect size. Polyester fabric is securely sewn to each disc to increase occlusion. The device is visible under X-ray.
ASD occluder device Features
Modified rigidity and flexibility for different type of occluders - greater stiffness of Atrial Septal Defect Occluder (ASDO) offers excellent supporting force for big disks.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Atrial Septal Defect Occluder (ASDO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use ASD Occlusion Device
The MemoPart™ ASD Occluder is a percutaneous, transcatheter, atrial septal defect closure device intended for the occlusion of atrial septal defects (ASD)in secundum position or patients who have undergone a fenestrated Fontan procedure and who require closure of the fenestration.
Patients indicated for ASD closure have echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overload(i.e.,1.5: 1 degree of left-to-right shunt or RV enlargement ).
Ordering Information
Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device |
A |
B LA Disc Diameter (mm) |
C |
H |
|
FQFDQ- Ⅰ 06 |
6 |
6 |
16 |
14 |
3 |
|
FQFDQ- Ⅰ 07 |
7 |
7 |
21 |
17 |
3 |
|
FQFDQ- Ⅰ 08 |
8 |
8 |
18 |
16 |
3 |
|
FQFDQ- Ⅰ 09 |
9 |
9 |
23 |
19 |
3 |
|
FQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
FQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
FQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
FQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
FQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
FQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
FQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
FQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
FQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
FQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
FQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
FQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
FQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
|
FQFDQ- Ⅰ 26 |
26 |
26 |
40 |
36 |
4 |
|
FQFDQ- Ⅰ 28 |
28 |
28 |
42 |
38 |
4 |
|
FQFDQ- Ⅰ 30 |
30 |
30 |
44 |
40 |
4 |
|
FQFDQ- Ⅰ 32 |
32 |
32 |
47 |
42 |
4 |
|
FQFDQ- Ⅰ 34 |
34 |
34 |
49 |
44 |
4 |
|
FQFDQ- Ⅰ 36 |
36 |
36 |
51 |
46 |
4 |
|
FQFDQ- Ⅰ 38 |
38 |
38 |
54 |
50 |
4.5 |
|
FQFDQ- Ⅰ 40 |
40 |
40 |
56 |
52 |
4.5 |
|
FQFDQ- Ⅰ 42 |
42 |
42 |
58 |
54 |
4.5 |
|
FQFDQ- Ⅰ 44 |
44 |
44 |
60 |
56 |
4.5 |
|
FQFDQ- Ⅰ 46 |
46 |
46 |
62 |
58 |
4.5 |
|
FQFDQ- Ⅰ 48 |
48 |
48 |
64 |
60 |
4.5 |
|
FQFDQ- Ⅰ 50 |
50 |
50 |
66 |
62 |
4.5 |
Hubless Atrial Septal Defect (ASD) Occluder
|
Catalogue No. Device |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅰ 06 |
06 |
6 |
16 |
14 |
3 |
|
WTFQFDQ- Ⅰ 07 |
07 |
7 |
21 |
17 |
3 |
|
WTFQFDQ- Ⅰ 08 |
08 |
8 |
18 |
16 |
3 |
|
WTFQFDQ- Ⅰ 09 |
09 |
9 |
23 |
19 |
3 |
|
WTFQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
WTFQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
WTFQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
WTFQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
WTFQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
WTFQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
WTFQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
WTFQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
WTFQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
WTFQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
<span style="font-family |
Personne à contacter : medical lepu, 86 10 80120666
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
|
Cette page concerne les importateurs et exportateurs de MemoPart™ Atrial Septal Defect (ASD) Occluder Rechercher dans la catégorie : Médical Rechercher dans la catégorie : occluder, defect, atrial, septal, memopart™ |
Tuesday 30 August 2016
Prix : 10,00 €
19003Fashion aviator sunglasses, ladies style. Sample lenses category 3, lens can be produced lighter or darker.Shiny gold frame with pink painting on temples, crystal pink tips.Smoke to pink gradient lenses. Also can be made in other colors.Metal hinge.Delivery time: 45 daysLens features...
Yiwu Fashion Zone Eyewear Co., Ltd muv
- 322000 - YIWU
- 86 0579 85557735
- 0579 15868988024
Tuesday 24 September 2013
Quantité : 1000 - Prix : 1 000,00 €
Soudure haute fréquence, des tuyaux HFI, ERW, Tuyaux en acier restes explosifs de guerre, la résistance tubes soudés électriques, tubes en acier restes explosifs de guerre Fournisseurs, restes explosifs de guerre tubes en acier Exportateurs Dans soudé processus de production haute...
Sunny Steel Tubosacero Ltd.
- tubosacero
- Shanghai - 闸北
- 862133780199
- 862161851035
Wednesday 04 November 2015
Quantité : 100 - Prix : 10-50USD
ISO/TS16949 Manufacturer Ductile Iron Casting Foundry Specification Ductile iron casting's specification according to custom drawing. Please kinldy provide us your drawing. Description Iron / Steel Castings: 1) Process: Resin sand/Green Sand/Investment Casting 2) Specification: 1...
Shanxi Qinghui Mechanical Manufacture Co., Ltd.
- 048000 - Jincheng
- (+86) 356 3875978
Paiement sécurisé