PN3000-HFNC High Flow Nasal Cannula
Quantité : 5000 units Prix : USD 15--USD 2200
Pigeon heated high flow cannula(HFNC) oxygen therapy is a form of non –invasive respiratory support,which comprises an air oxygen blender mixer, respiratory humidifier, a single heated circuit and a heated nasal cannula.It delivers adequately heated and humidified medical gas up to 60L/min,and is considered to have a number of physiological effects.
Working Principle of PN3000-HFNC High Flow Nasal Cannula
Pigeon adult HFNC pigeon adopts a soft, comfortable, lightweight breathing circuit and a unsealed high-flow nasal oxygen cannula to deliver a mixed high-flow gas to patient. Since the mask is not required, the patient can eat and talk without being affected while receiving treatment. After finishing machine connection, gas and oxygen come into blender and be adjusted to certain concentration, inpired gas goes through humidifier and is heated to be with certain temperature and humidity, the machine has automatic temperature detection function, which makes patients' breath smoothly and comfortably.
Features of PN3000-HFNC High Flow Nasal CPAP Cannula
Automatical temperature detection
Stable performance
Mechanical type blender design.
Medical air compressor can be optional in the case of absence or failure of central air supply.
Specification of PN3000-HFNC Nasal Cannula Max Flow
|
Adjustment of Oxygen Concentration |
Mechanical |
||
|
FiO2 |
21%-100% |
||
|
Flow |
6-60LPM |
||
|
Pressure of gas source |
Air/Oxygen@0.3-0.4 Mpa |
||
|
Blender Alarm |
When gas supply pressure difference > 0.1 Mpa |
||
|
Blender Alarm Noise |
>57 dB(A) |
||
|
Accuracy of FiO2 |
0.03 |
||
|
Humidifier Supply Voltage/Frequency |
220V/ 110V 50/60Hz |
||
|
Humidifier Temperature monitoring |
0-75℃ |
||
|
Humidifier Heater Plate Over-temperature Cut Off |
95±5℃ |
||
|
Heater Wire(Max.) |
22V-,2.73A, 60W, 50/60Hz |
||
|
Humidifier Temperature control settings |
Heated wire mode(mode indicator lighted) |
||
|
Temperature grade(with indicator status) |
Continuous flow range |
Delivered patient temperature |
|
|
P1 (●○○) |
5L/min-60L/min |
25-29℃ |
|
|
P2 (●●○) |
5L/min-60L/min |
29-35℃ |
|
|
P3 (●●●) |
5L/min-60L/min |
35-39℃ |
|
|
Non-heated wire mode(It is not recommended in adult HFNC. Operate manual of humidifier show details) |
|||
Pigeon Medical specializes in manufacturing respiratory therapy equipment & high flow oxygen therapy devices. Main products are air-oxygen blender, medical air compressor, respiratory humidifier and high-flow nasal cannula. We also have considerable experience in providing solutions for non-invasive, invasive ventilation and high flow nasal therapy.
Personne à contacter : Zhou Alex , +18 8 98 65 17 88
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
|
Cette page concerne les importateurs et exportateurs de PN3000-HFNC High Flow Nasal Cannula Rechercher dans la catégorie : Pro / B2B Rechercher dans la catégorie : high, pn3000, flow, cannula, hfnc, nasal |
Thursday 10 April 2014
Quantité : 1000
Spécifications du produit / Modèles Code de l'article: C500, C650, C750, C1000 Couleur: Transparent Capacité: 500ml, 650ml, 750ml, 1000ml application Adapté pour l'utilisation dans les emballages alimentaires, plats à emporter, à l'aide de micro-ondes. Autres informations haute...
QUI PHUC TRADING-SERVICE-PRODUCTION CO.,LTD
- quiphuc
- 84 - HCM city
- +84 (0)8 54263229
- +84 9 74 00 02 86
Saturday 02 August 2014
Quantité : 300pcs - Prix : 10-50USD/PC
Ingrédients: talc, mica, huile minérale, kaolin, dioxyde de titane, stéarate de magnésium, le palmitate d'isopropyle, la lanoline, parahydroxybenzoate de méthyle, parahydroxybenzoate de propyle, BHT. Peut contenir: Mica et le dioxyde de titane, Des oxydes de fer, bleu outremer, l'oxyde Verts...
ShenzhenMakefayCosmeticsCo.,Ltd
- 518000 - Shenzhen
- 0755 89391213
Tuesday 26 November 2013
Quantité : neduction - Prix : 1euro
CHER Mr dans le soucie d'étendre sont contrôle du marche du papier A4 80 G Le GROUPE EVASORA LTD ,mes a votre disposition des papier de qualité haut de gamme a des prix défiant toute concurrence recherche distributeur Papier A4 80g vente de papier a4 80g marque double a et navigateur...
GROUPE EVASORA LTD
- 237 - DOUALA-BUEA
- +237 690117124
Paiement sécurisé