Chine (Rép. pop) Pro / B2B
Pro / B2B

Serum Separation Tubes

Golden VacTM SST plain serum blood tube gold-top vacuum blood tubes for serum determinations in chemistry, immunology, and serology tests. The Serum Separation Tube is Serum Blood Collection Tube.

Description of Serum Separation Tubes

01

Coated with ultrasonically spray-dried microscopic silica particles which activate blood clotting.

02

Contain an inert polymer gel that separates the serum from the blood clot during centrifugation, preventing contamination of the serum.

03

Gently mix the blood collection tube by inverting 5-6 times immediately to activate clotting after blood drawing.

04

Allow the tube to stand for 30 minutes or until the clot is formed before centrifuging.

05

Centrifugation: 1800-2200 g for 8-15 minutes at 18-25° C.

Specification of Serum Separation Tubes

Cat. No

Volume/ml

Size/mm

Additive

Separator

Material

Cap Color

Closure

GD040SGC

4.0

13X75

Clot Activator

Gel

PET/GLASS

gold top serum separator tube

Safety Cap+Rubber

GD040SGC2

4.0

13X100

Clot Activator

Gel

PET/GLASS

Safety Cap+Rubber

GD050SGC

5.0

13X100

Clot Activator

Gel

PET/GLASS

Safety Cap+Rubber

GD060SGC

6.0

13X100

Clot Activator

Gel

PET/GLASS

Safety Cap+Rubber

GD080SGC

8.0

16X100

Clot Activator

Gel

PET/GLASS

Safety Cap+Rubber

GD080SGCR

8.0

16X100

Clot Activator

Gel

PET/GLASS

Rubber Stopper

GD085SGC

8.5

16X100

Clot Activator

Gel

PET/GLASS

Safety Cap+Rubber

GD085SGCR

8.5

16X100

Clot Activator

Gel

PET/GLASS

Rubber Stopper

All Sst blood vial are supplied in 1000pcs or 1200 pcs/ctn.

Gongdong Medical offers a gold-top SST tube.

Customization is supported.

To know more about serum gel separator tube, click "What is a yellow-top serum separation tube".

How Do You Separate Serum from SST Tube?

When using a serum gel blood tube, collect the specimen using standard venipuncture technique. Gently invert the tube five times to mix the clot activator with the blood. Allow the tube to clot for 20-30 minutes in a vertical position. Centrifuge the tube for 10-15 minutes at about 1300-1800 xg. The centrifuge RPMs will differ depending on the centrifuge and rotor used. The gel barrier will develop, keeping the serum and clot apart.

Why Are Serum Separator Tubes Used?

The serum in blood tubes is used when they want to test the serum of the blood. For tests like (NA, K, CL, CO2, LD, HDL) any type of chemistry. It is also used for tests like neonatal bilirubin or an AFP non maternal. There is special gel that separates blood cells from serum, as well as particles to cause blood to clot quickly. The blood sample may then be centrifuged, allowing the clear serum to be removed for testing.

As a professional lab consumables manufacturer, Bohao has high-quality medical consumables. Welcome to contact us if needed.

Localisation : No.10,Beiyuan Ave., Economic Development Zone,Huangyan,Taizhou,Zhejiang,China, 318020 Taizhou,
Personne à contacter : wang alex, 0576 84115678

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
Serum Separation Tubes

Rechercher dans la catégorie : Pro / B2B
Rechercher dans la catégorie :
serum, tubes, separation
Turquie 06370 Alimentaire
Machine de sucre

Dimanche 15 mars 2015

TAYSAN MAKINA CO. Sarl. Est une entreprise qui fait la production des machines types R entièrement automatiques et manuel à fabriquer du sucre en cubes dur en Turquie et aussi des machines à emballage alimentaires divers et sucre en morceaux depuis une expérience de dix ans. Avec...

Taysan Makina Ltd

  • taysanmakina
  • 06370 - Ankara
  • 0090 312 396 01 09
  • 0090 546 610 06 05
France 255086 Matériels occasions
Fibres de céramique isolation thermique des matériaux réfractaires

Samedi 13 juin 2015

Quantité : 100 - Prix : US$7.65

Description du produit: la fibre de céramique sont fabriqués à partir d'aiguilles punching couverture correspondant en céramique les fibres (com, st, hp, ha, hz). en utilisant les techniques de soufflage et de haute performance à ces produits offrent un supérieur performance isolante...

Zibo JC Eco-Tech Co., Ltd

  • 255086 - China
  • +86 15505335058
  • +86 533 3593322
Vietnam 700000 Meubles
Imitation Rattan chair - QP 254

Vendredi 03 mai 2024

Quantité : 720

PLASTIC IMITATION RATTAN CHAIR Aluminium chair with rattan strings. Solid and stable frame in imitation of bamboo (aluminum tube with wall thickness 2 mm) and rattan seat (artificial rattan headed inside hardened steel wire). Model: Rattan. Material: PP. Usage: Interior/out door...

Qui Phuc Company Limited

  • Luck06
  • 700000 - Ho Chi Minh
  • +84 9 86 58 28 62