Several Attentions about Using and Maintaining Chromatographic Columns

It is important for the experimenters to use and maintain chromatographic columns correctly. They should focus on many some things so as to protect the columns in the using process. Here we talk about several attentions.

Avoid changing pressure and temperature dramatically and any mechanical vibration. Sudden changes in temperature affect the filling conditions in the columns. And sudden changes of column pressure may loosen the fillers. Consequently, people should adjust the flow rate of the fillers slowly to protect the fillers.

Change the composition of the solvents gradually. The experimenters should change the composition of the solvents gradually, especially in the reversed-phase chromatography.

Do not backwash the columns. Generally speaking, chromatographic columns cannot be back washed. But, if the manufacturer specifies the columns can be back washed, the experimenters can remove the impurities through backwashing.

Choose a suitable mobile phase. The suitable mobile phase is chosen to avoid the destruction of the stationary phase. Sometimes it is a better way to install a pre-column which has the same substrate and little impact on the reaction, where the mobile phase will be pre-reacted before entering the analysis column.

Localisation : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Personne à contacter : Bruce Lu, +86 29 89284429

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
Several Attentions about Using and Maintaining Chromatographic Columns

Rechercher dans la catégorie : Divers
Rechercher dans la catégorie :
chromatographic, attentions, columns, about, maintaining, several, using
Russie 183038 Pro / B2B
Mobile diving complex

Sunday 08 July 2012

Quantité : 1 - Prix : negotiated

Mobile diving complex executed in double 20 ft marine containers with 60 m diver depth and diving station for operation of 2 working and 1 standing by divers. 1st container Diving complex: 20' marine container with additional door, illuminators and heat insulation, main switchboard...

MSCO

  • 183038 - Murmansk
  • +78 1 52 48 10 21
  • +79 2 16 66 33 86
Automatic Gear Pump Liquid Filling Machine FP-465

Tuesday 03 March 2026

Automatic Gear Pump Liquid Filling Machine FP-465 is designed and engineered to produce outstanding quality and precision filling suitable for various products like shampoo, hot sauce, lubricant oil etc. FP-465 can also replace piston or peristaltic module for the flexibility of filling demands...

Autopack Co.,Ltd

Tabletop Tablet / Capsule Counting Machine

Tuesday 03 March 2026

Quantité : 50

Tabletop Tablet / Capsule Counting Machine TC-100 is design for accurate counting and bottle filling of all kinds of tablets and capsules. FEATURES: - PLC control system. Easy operation by Touch screen - Highly accurate Counting Speed - Flap Nozzle for Non-Stop counting - Dust...

Autopack Co.,Ltd