Chine (Rép. pop) Divers
Divers

URR Cloth Ductwork

Prix : USD0.1-1000

URR (UNIFORM AIR VELOCITY, REDUCER, RETENTION)-N SERIES

URR cloth ductwork perfectly integrates uniform air velocity controlling technology with the internal retention ring system. URR cloth air duct system remains round when deflated, absorbing all advantages of both products, It presents more stable inner air velocity, more balanced inner pressure, better visual pleasing effect, easier installation, and higher cost-efficiency.

Advantage

More Stable Inner Air Velocity

Inner Air Velocity on Lengthwise Section

Under the same air supply condition, the internal air velocity curve of ordinary equant round duct is sharply descendant along with lengthwise direction, the air velocity tends to zero at the end cap; UR system can generally ensure stable internal air velocity.

Air Dispersion Direction Diagram of Ordinary Equant Round Duct

Due to vector superposition effect, there is wide difference in internal air velocity from inlet to end cap of ordinary equant round duct.

Air Dispersion Direction Diagram of UR System

Uniform air velocity inside UR system results in same air dispersion direction along the duct.

More Balanced Inner Pressure

Static Pressure Curve of Ordinary Equant Round Duct

Generally speaking, the air velocity is rapidly decreasing inside ordinary equant round duct. Since the static pressure regain leads to the increasing of dynamic pressure whereas less on-way resistance, the overall static pressure from inlet to end cap has a certain increase. PAD must be installed to balance static pressure.

Static Pressure Curve of UR System

Since UR system is cone-shaped from inlet to end cap, its on-way resistance is larger than that of ordinary equant round duct. Meanwhile, the internal air velocity is relatively uniform and the static pressure regain is lower. The test result turns out that UR system could basically achieve balanced inner static pressure as long as it is not exceptionally long.

Effectively Slow Down Temperature

Ordinary Equant Round Fabric Duct System

If ordinary equant duct is running with excessively high surrounding temperature or over-length, the inner air temperature lengthwise has a certain rise.The degree of temperature rise is relevant to duct length and temperature difference between insideand outside duct surface.

UR Air Dispersion System

The relatively high axial air velocity of UR system reduces the heating exchange time between the inner air and duct surface, which slows down and reduces the temperature rising. Meanwhile, as the decreasing of surface area along the rear duct results in smaller heating exchange contact area, that is conducive to further slow down and reduce temperature rising. The test result turns out that the temperature rising control efficiency of UR system has been improved for 70% compared with Ordinary equant round fabric duct.

Achieve More Uniform Airflow Distribution

UR System With Multi-Branches

Since the air velocity in main duct of UR system is completely stable and balanced while the included angle between duct surface and branch duct is slightly less than 90°, that is conducive to lead uniform air distribution to each branch.

Ordinary Equant round fabric duct with multi-branches

Different air velocity in main duct of Ordinary equant round fabric duct leads to different airflow supply in each branch, which causes the nearer the branch is to endcap, the more airflow the branch is to receive. ACD is required to balance airflow in each branch.

Advantages of URR Cloth Air Duct

More Balanced Inner Pressure

Effectively Slow Down Temperature

Achieve More Uniform Airflow Distribution

Inner Air Velocity on Lengthwise Section

Under the same air supply condition, the internal air velocity curve of ordinary equant round duct is sharply descendant along with lengthwise direction, the air velocity tends to zero at the end cap; UR system can generally ensure stable internal air velocity.

Air Dispersion Direction Diagram of Ordinary Equant Round Duct

Due to vector superposition effect, there is wide difference in internal air velocity from inlet to end cap of ordinary equant round duct.

Air Dispersion Direction Diagram of UR System

Uniform air velocity inside UR system results in same air dispersion direction along the duct.

Static Pressure Curve of Ordinary Equant Round Duct

Generally speaking, the air velocity is rapidly decreasing inside ordinary equant round duct. Since the static pressure regain leads to the increasing of dynamic pressure whereas less on-way resistance, the overall static pressure from inlet to end cap has a certain increase. PAD must be installed to balance static pressure.

Static Pressure Curve of UR System

Since UR system is cone-shaped from inlet to end cap, its on-way resistance is larger than that of ordinary equant round duct. Meanwhile, the internal air velocity is relatively uniform and the static pressure regain is lower. The test result turns out that UR system could basically achieve balanced inner static pressure as long as it is not exceptionally long.

Ordinary Equant Round Fabric Duct System

If ordinary equant duct is running with excessively high surrounding temperature or over-length, the inner air temperature lengthwise has a certain rise.The degree of temperature rise is relevant to duct length and temperature difference between insideand outside duct surface.

UR Air Dispersion System

The relatively high axial air velocity of UR system reduces the heating exchange time between the inner air and duct surface, which slows down and reduces the temperature rising. Meanwhile, as the decreasing of surface area along the rear duct results in smaller heating exchange contact area, that is conducive to further slow down and reduce temperature rising. The test result turns out that the temperature rising control efficiency of UR system has been improved for 70% compared with Ordinary equant round fabric duct.

UR System With Multi-Branches

Since the air velocity in main duct of UR system is completely stable and balanced while the included angle between duct surface and branch duct is slightly less than 90°, that is conducive to lead uniform air distribution to each branch.

Ordinary Equant round fabric duct with multi-branches

Different air velocity in main duct of Ordinary equant round fabric duct leads to different airflow supply in each branch, which causes the nearer the branch is to endcap, the more airflow the branch is to receive. ACD is required to balance airflow in each branch.

Where to Use the Cloth Ductwork

Post Air Supply Aress

Given high ambient temperature, large airflow and relatively long duct in such areas as machining workshop, URR air dispersion system maintains high and uniform air velocity by continuously changing conicity to achieve even air dispersion and significantly reduce temperature rising.

Large And High-Elevation Facility

Given large airflow and high ambient temperature in high and large space, UR air dispersion system is applied to obtain higher air velocity at each orifice and long air throw distance with aesthetic appearance.

High Demand For Even Air Dispersion

Given the high requirement of even air dispersion along the duct and strict control of end air velocity, the global leading design software Isox is used to calculate and generate continuously variable diameter UR system to identify as the best uniform velocity air dispersion system.

High Demand For Cost Efficiency

Given the high space and large airflow in such areas as logistics warehouse and cold logistics, both effective air dispersion and cost efficiency shall be taken into consideration. UR airdispersion system can not only ensure even air dispersion but also reduce overall cost because of less fabric consumption.

Durkeesox is one of professional duct sock suppliers. We provide Textile Ventilation, Nanosox Fabirc HVAC Duct, Insusox Pre-insulated air duct and so on. Want to know more? Please contact us.

Localisation : NO.8, West Renmin Rd., Gedian Development Zone, Hubei ,China, 436070 Hubei,
Personne à contacter : durkeesox durkeesox, 0086 0711 5919000

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
URR Cloth Ductwork

Rechercher dans la catégorie : Divers
Rechercher dans la catégorie :
cloth, ductwork
Indonésie 29431 Véhicule
2013 Yamaha Raptor YFZ450R

Mercredi 16 janvier 2013

Quantité : 100 - Prix : USD5159

Engine Type 449cc, 4-Stroke Single, Liquid Cooled w/Fan, Titanium 5-Valve DOHC Bore x Stroke 95mm x 63.4mm Compression Ratio 11.6: 1 Fuel Delivery Yamaha Fuel Injection (YFI), 42mm Ignition Digital TCI: Transistor Controlled Ignition Starting System Electric Transmission 5-Speed...

KRAMBA TRANSPORTATION

  • 29431 - Batam
  • 6285762075388
Espagne 46015 Hygiène / Santé
BUDDY STICKY ROLLER CLEANING - complete set - PR002101

Jeudi 29 août 2013

Quantité : 10 - Prix : 12,95 €

BUDDY STICKY ROLLER CLEANING - complete set - PR002101 EXCLUSIVE OFFER STICKY ROLLER CLEANING BUDDY Cleaning system is perfect for all household needs. Sticky Buddy makes one pass away dust, lint, food scraps and even pet hair. How does Sticky Buddy? This product has a very easy to use...

Fastocks Europe, S.L.

  • 46015 - Valencia
  • 902099937
Hong Kong 519015 Véhicule
Sell car alarms

Jeudi 16 mai 2024

Two way LCD car alarm system with engine start module Detecting method Rechargeable Li-battery Window roll up control Long range monitoring www.autosmartelec.com Localisation : 1015 central, 519015 Hong Kong, Personne à contacter : Helen Loa, 867563885632

Autosmart Electronic Co., Limited

  • 519015 - Hong Kong
  • 867563885632