Cooling Water Chiller SUNDI -45℃~300℃
It is important to choose the suitable heat conduction medium, to make sure that system works stably. To choose the suitable medium according to the working temperature of the system is essential.
How to Determine Freezing Water Flow Rate?
A lot of people will ask such a question when they buy a cold water machine -- how do you determine the freezing water flow of a refrigerated water unit? So which aspects should we consider the cold water flow?
1. Water pressure test of the unit in and out of the water pipe.
Detect the pressure value of the in- and out-water, then refer to instruction about the water flow under this circumstance and determine whether the water system is normal by looking at the description in the corresponding table or flow diagram of the unit. This difference is also used to determine which part of the water pipeline has a large resistance and make corresponding rectification plan and action.
2. The air inlet temperature of the compressor should be tested only when the refrigeration operation is carried out.
If the temperature of the refrigerated water chiller is tested lower than zero after running for 30 minutes, then water flow is not enough on water side heat exchanger which causes evaporation temperature and pressure to fall and cause freon in evaporator flow to the compressor suction duct in evaporation heat. That brings about the fact that the compressor suction temperature below zero. In addition, the evaporation pressure and evaporation temperature caused by low temperature setting should be excluded. However, the low-temperature unit can be considered normal as long as there is 6 ~ 8 ℃ overheat of compressor suction. So under normal water flow, the compressor suction temperature generally will be greater than 0 ℃. Temperature lower than this value should be ruled out water system problems.
3. The current needs to be tested when the pump runs.
By detecting the current of the pump of water industrial chiller and comparing with rated current, you can determine the actual water flow, whether its water flow is big or small. Refer to the parameters above, you can draw an exact water system testing analysis report.
Personne à contacter : Tony Tony, 0510 82303782
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
|
Cette page concerne les importateurs et exportateurs de Cooling Water Chiller SUNDI -45℃~300℃ Rechercher dans la catégorie : Biens d'équipement Rechercher dans la catégorie : chiller, 45℃~300℃, water, sundi, cooling |
Sunday 02 September 2007
LA CELLULETTE est la 1° sandale minceur avec tests d'efficacité effectués par un laboratoire Français agréé, prouvant un amincissement significatif en 28 jours d'utilisation. Une efficacité amincissante et anti capitons prouvée scientifiquement. Cette sandale présente une semelle...
deltapartners
- issy
- 92600 - ASNIERES SUR SEINE
- +33 1 41 11 34 34
Friday 01 February 2008
Quantité : 1 - Prix : 226,04 €
Camera analogique dans caisson aluminium (visière à installer sur mur ou plafond) avec capteur ultra sensible et diodes Infra rouge (vision nocturne). Fonctionne en couleur : luminosité normale, passe en noir et blanc quand l'éclairage devient insuffisant (fonctionne donc) 24 heures sur 24...
AS CONSEIL
- nebulis
- 92100 - Boulogne Billancourt
- 09 70 46 74 60
Saturday 20 February 2016
Quantité : 1000 MT PE - Prix : 300/mt CIF
Product Description Dried Kidney Beans 2014,Sugar Beans Specifications 1. Origin: Thailand 2. Crop: 2014 3. Quality: Grade One 4. Specifications: Size 220-240pcs/100g Moisture 16% max; Admixture 0.2% max; Imperfect: 2% max; Cooking time: less than 60min with hot water 5...
Khun Jack Partnership Ltd
- 5000 - Chaing Mai
- +66 9 68 75 20 43
Paiement sécurisé